Enclosed Ground Flare for Lean, Low-Hydrocarbon Produced Gas

Cairn India
Barmer, Rajasthan, India

Advanced combustion design maintaining stable operation on near-limit hydrocarbon concentrations.

17,000
m³/hr
Lean
Produced gas
Skid
Mounted
Enclosed flaring system for lean and contaminated produced gas at Barmer, Rajasthan.
The Overview
Cairn India Limited (Vedanta), via an oilfield services partner
Client
Upstream Production Operations
Sector
Engineering, Manufacturing, Testing, Commissioning
CRA Role
Enclosed flaring of lean and contaminated produced gas
Application
Delivered
Status
Produced gas
Inlet Gas

CRA partnered with an oilfield services company to engineer and deliver an enclosed flaring system for Cairn India Limited’s upstream production operations in Barmer, Rajasthan. The system was designed to safely combust lean and contaminated produced gas with very low hydrocarbon content, designed for stable combustion, environmental compliance and reliable operation in a remote desert environment. The solution focused on advanced combustion design and full subsystem integration to handle challenging gas characteristics under continuous operating conditions.

The Challenge

Safely Flaring Lean, Contaminated Produced Gas with Very Low Calorific Value

The oilfield services partner required a flaring solution capable of handling produced gas streams with extremely low hydrocarbon content and contamination, creating inherent combustion and stability challenges. The system needed to address the following constraints:

‍

• Very lean gas composition with limited calorific value
• Presence of contaminants requiring robust combustion containment
• Requirement for stable, enclosed combustion to meet safety and environmental norms
• Continuous operation in remote desert conditions at Barmer
• High reliability expectations under upstream production constraints

‍

The flare had to provide consistent ignition, stable flame retention, and controlled radiation while operating with a difficult and variable gas stream.

Our Solution

Custom-Engineered Enclosed Flare with Integrated Combustion and Safety Systems

CRA engineered and manufactured a fully integrated enclosed flaring system specifically designed for lean and contaminated produced gas applications. The solution emphasised combustion stability, maintainability and complete package delivery.

‍

Core Components Delivered

• Custom-designed enclosed flare with advanced combustion geometry
• Engineered burner optimised for lean gas combustion
• Pilot and Flame Front Generator ignition system
• Dedicated air blower for controlled combustion air management
• Fully integrated piping, instrumentation, and control systems
• Skid-mounted enclosure and structural framework

‍

Engineering and Validation

• Detailed structural design and layout engineering
• FEA simulations to validate mechanical integrity
• Radiation and noise analysis against site limits
• Electrical engineering and interlock logic for safe operation
• Maintenance-focused design provisions for long-term reliability

‍

Fabrication, Testing, and Commissioning

• Complete in-house fabrication of all mechanical and combustion components
• Factory testing of ignition, airflow, and control logic
• Fully skid-mounted delivery for rapid installation
• On-site commissioning and performance validation at Barmer

Results

Reliable Enclosed Flaring for Challenging Produced Gas Streams

• Stable combustion achieved on lean gas with very low hydrocarbon content
• Safe and controlled enclosed flaring of contaminated produced gas
• Reliable ignition and flame stability under continuous operation
• Compliance with safety, radiation, and noise requirements
• Integration into Cairn’s upstream production facilities
• Demonstrated performance in a remote desert operating environment

‍

Conclusion

CRA Demonstrates Proven Capability in Complex Gas Flaring

This project highlights CRA’s capability to engineer and deliver enclosed flaring systems for some of the most challenging upstream gas compositions. By combining advanced combustion design, in-house engineering validation, and fully integrated manufacturing, CRA provided Cairn and its oilfield services partner with a robust and repeatable solution for lean and contaminated produced gas. The Barmer installation reinforces CRA’s expertise in complete flare packages where combustion stability, safety, and reliability are critical under difficult operating conditions.

‍