High-Capacity 365,000 SCMD Enclosed Ground Flares for Gas Gathering Stations

ONGC
Assam, India

Low-flame, low-noise operation inside active plant boundaries, designed to API 521/537.

365,000
SCMD
≥ 98%
DRE
API 521/537
Standard
Enclosed ground flare engineered by CRA at an ONGC gas gathering station in Assam, seen behind its staging control valves.
The Overview
ONGC (Oil & Natural Gas Corporation)
Client
Three gas gathering stations, ONGC Assam Asset
Sites
Low-emission destruction of excess process gas
Application
Oil & Gas, Upstream Processing
Sector
Delivered
Status

CRA was entrusted with the design, engineering, manufacturing, and supply of high-capacity Enclosed Ground Flare (EGF) systems for multiple gas gathering stations at ONGC’s Assam Asset. The systems were engineered to provide safe, reliable destruction of hydrocarbon-rich process gases generated during normal, upset, and emergency operating conditions. The enclosed flare systems were specifically designed to achieve high destruction efficiency while maintaining low visible flame, minimal noise, and controlled thermal radiation. This enabled installation within active plant areas subject to stringent safety, environmental, and operational constraints. The project reflects CRA’s capability to engineer robust flaring solutions for large-capacity gas handling under complex gas compositions and fluctuating flow conditions.

The Challenge

Managing High-Volume Hydrocarbon Flaring Within Active Gas Processing Facilities

ONGC required a flaring solution capable of safely handling large volumes of process gas generated across multiple gas gathering stations. The key challenges included:

‍

  • Safe disposal of hydrocarbon-rich gas streams during normal, upset, and emergency conditions
  • Strict environmental requirements demanding minimal visible flame, smoke, and noise
  • Installation within operational plant areas with tight safety and radiation limits
  • Variable gas composition and flow rates requiring stable combustion performance
  • Long-term reliability under continuous and intermittent flaring duty

‍

The system needed to deliver consistent, high-efficiency combustion while maintaining operational safety and regulatory compliance.

Our Solution

Engineered Enclosed Ground Flare Systems for Safe, High-Efficiency Gas Disposal

CRA engineered and supplied enclosed ground flare systems tailored to the operating conditions at each of the three stations, enabling safe disposal of hydrocarbon-rich process gases. The solution focused on stable combustion across variable flow conditions with low radiation, minimal noise and low visible flame within active plant environments.

The enclosed configuration allows controlled oxidation of flare gas within a refractory-lined combustion chamber, limiting flame visibility and heat dispersion. The systems were designed to operate reliably during normal, upset, and emergency flaring scenarios, following API 521 and API 537.

‍

Design and Manufacturing

Robust Combustion Design Backed by Precision Manufacturing

CRA executed the complete design and manufacturing scope in-house, with full control over combustion performance, mechanical integrity, and quality compliance.

‍

Design Engineering

  • Combustion chamber geometry optimised for hydrocarbon-rich gas with variable composition
  • Engineered air ingress and mixing arrangement for complete oxidation and flame stability
  • Refractory lining designed for sustained high-temperature operation and long service life
  • Radiation and noise containment engineered for installation within operating plant areas
  • Design aligned with API 521 and API 537

‍

Manufacturing and Quality Control

  • In-house fabrication of combustion chambers, structural components, and internals
  • Controlled refractory installation and curing processes
  • Dimensional inspection and weld quality verification at each fabrication stage
  • Pre-dispatch inspection and documentation ahead of site integration

‍

This integrated design-to-manufacturing approach supported reliable system performance, repeatable quality, and smooth deployment across multiple gas gathering stations.

‍

Results

Stable, High-Efficiency Enclosed Flaring Across Multiple Stations

Reliable enclosed flaring across multiple gas gathering stations

‍

  • Achieved stable, high-efficiency combustion across all operating scenarios
  • Eliminated visible flame and significantly reduced noise and radiation levels
  • Safe disposal of hydrocarbon-rich gases under variable flow conditions
  • Met ONGC’s environmental, safety, and operational performance expectations
  • Delivered a robust flaring solution suitable for long-term upstream operations
Conclusion

Reliable Enclosed Flaring, Proven in Operation

This multi-site project demonstrates CRA’s capability to design and supply high-capacity enclosed ground flare systems for demanding upstream oil and gas applications. By combining advanced combustion engineering, robust mechanical design, and strict adherence to international standards, CRA delivered a reliable, low-emission solution for ONGC’s Assam gas gathering facilities.

The successful commissioning at all three stations reinforces CRA’s expertise in engineered flaring systems that balance safety, performance, and sustainability, particularly in live plant environments where combustion stability and emission control are critical.