Enclosed Flares for Landfill Closure

Enclosed landfill gas flares for closed and capped sites, with turndown up to 100:1 as the gas declines.

Enclosed Flares for Landfill Closure
Quick Enquiry
Talk to an engineer about your project.
Send us your requirements and we will get back within 2 business days
Interested in : 
Enclosed Flares for Landfill Closure
Your request has been received. A technical specialist will connect with you shortly.
Oops! Something went wrong while submitting the form.
Overview

Landfill gas destruction through the long decline after closure

CRA's enclosed landfill gas flares destroy the gas from closed and capped sites with turndown up to 100:1, so combustion stays stable as the flow falls year after year.

Destruction efficiency

>98%

Turndown

Up to 100:1

Standards

EPA NSPS/EG, API 537

Operation

Unattended

Technology Explained

What does a flare do at a closed landfill?

After capping, the gas collection system keeps drawing gas from the wells and sends it to the flare, where it burns at ground level inside an enclosure. As the waste ages, the flow and methane content fall, and the flare's automatic controls follow the falling flow to hold the combustion temperature that the destruction efficiency relies on.

How it works

The flare connects to the site's gas collection system and runs unattended for long periods between visits.

1
Gas drawn from the wells

The collection system draws gas from the capped waste.

2
Flame proven

The flare lights and proves its flame automatically.

3
Enclosed combustion

The gas burns at ground level, with the flame out of sight.

4
Falling flow followed

Automatic control follows the gas flow as it declines.

5
Safe shutdown

On a fault, the flare shuts down safely and raises an alarm.

Key Benefits

1
Turndown up to 100:1

The flare holds a stable flame as the gas flow falls over the years.

2
Over 98% Destruction

Enclosed combustion destroys more than 98% of the methane sent to the flare.

3
Unattended Running

Automatic start, flame proving and shutdown suit closed sites that are rarely staffed.

4
Built for Landfill Gas

Materials are selected for the H₂S, moisture and siloxanes in landfill gas.

5
Emissions on Record

The exhaust can be sampled to report emissions under the site's permit.

Projects That Push Boundaries

See all Case Studies
Wastewater & Landfill
Landfill Gas Flare System at Repi Landfill, Addis Ababa, Ethiopia
CGAASWRDPO, Addis Ababa
Ethiopia

CRA's first Sub-Saharan Africa landfill gas installation, delivered under a single contract from design through commissioning.

600 Nm³/h

LFG Capacity

≥ 98%

DRE

10 m, 1.8 m Dia

Flare Tower
Read case study
Wastewater & Landfill
Enclosed Ground Flare for the Gorai Landfill Closure, Mumbai
MCGM
Mumbai, India

Enclosed ground flare system for MCGM's Gorai dumpsite closure, commissioned and in continuous operation since.

Flare with gas train

Scope

Landfill Gas (LFG)

Gas Type

CPCB Norms

Design Basis
Read case study
See All Case Studies

The CRA Edge

Proven Expertise

CRA has more than 30 years of experience in gas handling and flare engineering.

In-House Strength

Design, R&D and manufacturing are carried out under one roof.

Global Compliance

ISO 9001 certified through TÜV NORD, with designs aligned with ASME, API and CE.

Tailored Solutions

Designs are customised to the process needs and the regulations that apply at site.

Applications

Closed landfills
Post-closure gas management
Odour control
Oversized flare replacement
Capped cells
Gas migration control
Methane emission control
Municipal landfill closure

Our Resources

Get all the technical details and resources you need in one place.

Tecnical Datasheet
Download
Tecnical Datasheet
Download
Tecnical Datasheet
Download
Tecnical Datasheet
Download

Frequently Asked Questions

Get all the technical details and resources you need in one place.

No items found.

Frequently Asked Questions

Why does a closed landfill still need a flare?

Waste keeps producing gas for many years after a landfill is capped. Collecting and burning it controls odour, lowers the risk of fire and gas migration and cuts methane emissions.

What turndown does a closure flare need?

Gas flow at a closed site falls steadily over the years, so the flare needs a wide operating range. CRA's landfill gas flares offer turndown up to 100:1.

Can an oversized flare be replaced?

Yes. Where the original flare is now too large for the gas that remains, CRA can supply a flare sized for the present and projected flows.

Which standards do the flares follow?

CRA's landfill gas flares are designed in line with EPA NSPS/EG and API 537, with destruction efficiency above 98%.

What data does CRA need to size a landfill closure flare?

CRA needs the present and projected gas flow, the methane content, the collection system pressure and the site conditions.

Custom engineered. Properly scoped.